INSTRUCTION MANUAL
HS-504
REVISION F
Hoffman Specialty
®
Series 1140 and 1141
Temperature Regulators
CAUTION
FOLLOW ALL INSTALLATION AND
OPERATING INSTRUCTIONS.
TURN OFF WATER OR STEAM
BEFORE SERVICING.
WEAR HEAT-RESISTANT GLOVES
BEFORE MAKING ADJUSTMENTS.
OPEN SUPPLY VALVES SLOWLY TO
PREVENT WATER HAMMER OR
SUDDEN SHOCK.
HANDLE REGULATOR WITH
EXTREME CAUTION. DO NOT LIFT
REGULATOR BY ANY EXTERNAL
TUBING. DO NOT KINK OR TWIST
TUBING AND AVOID BENDING IT ON
A RADIUS LESS THAN 4" (100 mm).
THE SENSING BULB MUST NOT BE
EXPOSED TO TEMPERATURES THAT
EXCEED THE RANGE LISTED ON THE
NAME PLATE.
ALARMS OR CUT-OFFS SHOULD BE
INSTALLED ON CRITICAL
APPLICATIONS TO INDICATE
REGULATOR FAILURE. A LEAK
COULD CAUSE THE ACTUATOR TO
LOSE ITS CHARGE AND CAUSE THE
SYSTEM TO OVERHEAT.
FAILURE TO FOLLOW THIS CAUTION
MAY RESULT IN PROPERTY DAMAGE
OR PERSONAL INJURY.
IMPORTANT: If you are uncertain as to the product’s
a
daptability for your application, please call the factory or
an authorized representative before installing or using the
product.
IMPORTANT: Do not install Series 1141 Temperature
Regulators in applications where ambient temperature
exceeds the regulator's set control temperature.
!
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - Temperature Regulators

INSTRUCTION MANUAL HS-504 REVISION FHoffman Specialty®Series 1140 and 1141Temperature RegulatorsCAUTION• FOLLOW ALL INSTALLATION AND OPERATING INSTRUC

Seite 2 - VALVE INSTALLATION

10Problem:2. System Temperature Higha. Cause: Bypass gate valve is open.Solution: Close the valve.b. Cause: Capillary has kink. Sharp bend willstop si

Seite 3 - BULB INSTALLATION

THERMOSTATICBULBRELIEFVALVEHOTWATEROUTLETDRAIN ANDBLOW-OFFCOLDWATERINLETSTORAGE HEATERTOTRAPVACUUM BREAKERTEMPERATUREREGULATORSTEAMINLET&q

Seite 4 - INSTALLATION

Xylem Inc. 8200 N. Austin Avenue Morton Grove, Illinois 60053 Phone: (847) 966-3700 Fax: (847) 965-8379www.xyleminc.com/brands/bellgossettBell & G

Seite 5 - MAINTENANCE

OPERATING PRINCIPLEThis Series 1140 regulator automatically controls theflow of steam, water or other medium passing throughits valve by responding to

Seite 6 - ACTUATOR ON TWO-WAY VALVES

THERMOSTATIC BULBBUSHINGGASKETFLANGEBUSHING SCREWARMORED CAPILLARY TUBING1" NPT ON 1/2" TO 2" NPT VALVES1-1/4" NPT ON 2-1/2"

Seite 7 - ACTUATOR ON THREE-WAY VALVES

4THERMOSTATIC BULBINSTALLATIONFOR THREE-WAY VALVES1. Install the bulb as close as possible to the outlet of the mixed water line. See Figure No. 7.2.

Seite 8 - WHEN IN NEED OF INFORMATION

TEMPERATURE ADJUSTMENTThis regulator can be set to control at any temperaturewithin the limits of the temperature range stamped onthe name plate. Aft

Seite 9 - Troubleshooting:

6CHANGING A THERMOSTATICACTUATOR ON TWO-WAY VALVESThe Thermostatic Actuator used on the Series 1140 reg-ulators is shown in Figure No. 11. All actuat

Seite 10 - Steam Valve Only

CHANGING A THERMOSTATICACTUATOR ON THREE-WAY VALVES1. Secure all water to valve and outlet from valve.2. Drain pipe line below location of thermostati

Seite 11 - TYPICAL INSTALLATIONS

8THREE WAY MIXING VALVESIMPORTANT: When installing a three-way mixingvalve, it is necessary that return circulation be piped tofeed the cold water

Seite 12 - Fax: (847) 965-8379

START UP PROCEDURE1. Make sure inlet gate valve is closed.2. Open outlet gate valve and all equipment drainvalves. Allow system to drain completely.3.